Features of the detector system:
- Free-mount lens option
- Mountable in optical setup
- Wavelengths within 632 to 800 nm (can be custom-built)
- Trans-impedance Amplifier included with gain 80kΩ
- Load Impedances 50 Ω
- Frequency up to 116 MHz
- Analogue output readable via oscilloscope
- Flexible diode gain via external bias voltage
Operation manual:
- connect a coaxial cable with SMA connector to the HV port.
- provide -28 V on the other end.
- Limit the DC current 0.03 Amp.
- Connect a coaxial cable with SMA connector to the signal port.
- Connect the end of the cable to the oscilloscope with 50 Ohm termination.
Usage:
- Learn the function of the photodiode.
- Infrared light detection.
- Any kind of optical setup that involves an infrared laser.